time2023/02/20
Solve way:connect the power
Cause: Faulty fuse and bad equipment on the part of external power source .
Solve way:Replace
Cause:Faulty lamp.
Solve way:Replace
Cause:Faulty printed circuit board(PCB)
Solve way:Replace
Cause :Faulty line in GUN
Solve way:Replace
Cause:Faulty in high-voltage generation part
Solve way:Replace
Cause:Faulty trigger switch
Solve way:Replace
2. Problem:The powder would not be fluidizing
Cause:The fluidizing air hose is not connected or compressed air is not input
Solve way:Connect after checking
Cause:Faulty fluidizing plate
Solve way:Replace
Cause:Faulty operation of pressure reduction valve
Solve way:Replace
3. Problem:The gauge hands of CONVERYING AIR and DOSING AIR do not move during
operation
Cause:operation mistake:The power switch is not pressed
Solve way:Turn on the power switch
Cause:The trigger is not pulled
Solve way:Check while pulling the trigger
Cause:Faulty SOLENOID valve
Solve way:Replace
Cause:Faulty PCB
Solve way:Replace